HOTLINE: 400-666-5819
Microinverter
Name:Microinverter-EVT560

The EVT560 Microinverter as a cutting-edge spokesman for the microinverters in the new era, has full sincerity and devotion to stability, details and more advanced tech. EVT560 seeks to enable best improved solar energy harvest, highest possible reliability, much simplified installation and most efficient management of solar power systems.

Each EVT560 is individually connected to one solar panel with every MPPT(Maximum Power Point Tracking) respectively for every panel. This unique configuration minimizes the negative impact from environment such as shading, dust, orientation or panel aging and eliminates the possibility of single-point failure, thus improving the system’s harvest to the largest extent

 

Highlights

* High-quality energy harvest with high MPPT accuracy

* Concentrated reliability and stability

* No single-point failure

* Improved safety with integrated complete set of protection functions

* Lifetime free remote monitoring at solar panel’s level

* Flexibly adapted to almost all 60-cell or 72-cell panels

* Easy installation

* Long life time

Micro-inverter Datasheet

Model

EVT560

Input Data (DC)

Recommended input power range(STC)

180W-360W*2

Maximum input DC voltage

54V

MPPT voltage range

24V~42V

Full load MPPT voltage range

28V~42V

Start voltage

24V

Cut-off voltage

18V

Maximum input current

9.5A*2

Maximum DC short circuit current

15A

Output Data (AC)

Maximum output power

560W

Maximum output current

2.55A

Nominal grid voltage

220V/230V

Nominal grid frequency

50Hz/60Hz

Grid frequency range*

165V~265V

Grid frequency range*

47~51.5Hz/57~60.6Hz

Power factor

>0.99

Total harmonic distortion

<3%

Nighttime power consumption

<100mW

Maximum units per branch

10units(12AWG Cable)

Efficiency

Peak inverter efficiency

95.8%

CEC efficiency

95.1%

MPPT efficiency

99.9%

Mechanical Data

Dimensions (WxHxD)

248mm*236mm*27.5mm

Weight

2.4kg

Enclosure environmental rating

IP67 (refer to IEC 60529)

Cooling method

Natural cooling

Overvoltage level

Panel side II / AC side III (refer to IEC 62109-1)

Features

Safety standard

EN 62109, AS 4777,IEC61727

Compliance

EN 61000-6-1, EN 61000-6-3, EN 61000-6-2, EN 61000-6-4, EN61000-3-2, EN61000-3-3

Grid Standard

VDE-AR-N-4105, VDE 0126-1-1, IEC 61727, AS4777,EN50438, EN62109,IEC 60068 61683

General parameters

Ambient temperature range

-40℃~+65℃ 

Operating temperature range

-40℃~+65℃ 

Relative humidity

0%~98% (no condensation) 

Maximum altitude

2000m

Isolation type

High frequency transformer isolation

Commutation

PLCC (Power Line Carrier Communication)

Lifetime

25 Years

E-Mail:

info@envertec.com
sales@envertec.com
tech@envertec.com

Follow us:

            